Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use - Wilo DrainLift XS-F Einbau- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DrainLift XS-F:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
20
2.5 Safety instructions for inspection and installation work
The operator must ensure that all inspection and installation work is carried out by autho-
rised and qualified personnel, who are sufficiently informed from their own detailed study
of the operating instructions.
Work to the pump/unit must only be carried out when at a standstill.
2.6 Unauthorised modification and spare part production
Modifications to the pump/unit are only permissible after consultation with the manufac-
turer. Original spare parts and accessories authorised by the manufacturer ensure safety.
The use of other parts can nullify the liability from the results of their usage.
2.7 Improper use
The operating safety of the supplied pump/unit is only guaranteed for conventional use in
accordance with Section 4 of the operating instructions. The limit values must on no
account fall under or exceed those specified in the catalogue/data sheet.
3 Transport and interim storage
Immediately after receiving the product:
• Check the product for damage in transit
• If there is damage in transit, take the necessary steps with the shipping company within
the required period.
CAUTION! Risk of damage!
Incorrect transport and interim storage can cause damage to the product.
• The unit must be protected from humidity and physical damage during transport and
interim storage.
• The unit is frost-resistant when stored at temperatures down to –20 °C. When the unit
is installed, however, do not allow water left in the reservoir to freeze.

4 Intended use

The DrainLift XS-F is a sewage lifting unit for restricted use (according to DIN 1986-100
and DIN EN 12050-3) which is ready to be directly connected to an wall hung toilet. The
unit fulfils all conditions for front wall installation, especially where a toilet or shower must
be installed, particularly in cellars or basements, during modernisation or restoration work.
Faeces and toilet paper are pumped into the on-site collector pipes.
The unit disposes of sewage for a single toilet or an additional washbasin, a shower and/or
a bidet, where the waste water cannot be directed to the canalisation via a natural fall, or
for waste water which accumulates below the backflow level.
• All connected drainage points must be in the same room as the unit (limited use of the lif-
ting unit).
• It is designed for a small number of users and there must be another toilet above the back-
flow level.
• The connection of additional drainage fixtures such as a washing machine, dishwasher or
bathtub is prohibited by DIN EN 12050-3.
• The unit must be operated with a cistern with a capacity of at least 6 litres. When the flus-
hing water is less than 6 litres, for example on dual-flush toilets, satisfactory operation is
not guaranteed.
• The system is only suitable for domestic sewage as defined in EN 12056-1.
CAUTION! Risk of damage!
Inappropriate materials in the system can cause damage to the product.
• Never put hygiene products, paper towels, moist toilet paper, leftover food, solvents,
chemicals, grease etc. in units for restricted use.
• Never put solid materials, fibrous materials, tar, sand, cement, ash, coarse paper,
rubble, refuse, butcher's waste, grease, oil or swimming-pool water in the unit.
WILO AG 11/2007

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis