Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; Scope Of Delivery - VOLTCRAFT LSG-10 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LSG-10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Intended Use

- Measuring and displaying electrical voltage in the range of overvoltage category III (up to max. 300V
against earth potential, pursuant to EN 61010-1) and all lower categories. The measuring device and
equipment must not be used in the overvoltage category CAT IV (e.g. at the low voltage installation
source.)
- Displays direct and alternating voltage up to a maximum of 400 V
- Contact-free cable search in powered-down and live installations in the wall, floor or ground
- Tracing the signal through transmitter and receiver
- Finding cable breaks and short circuits
- Assigning and finding fuses and their circuits
- Finding and tracing metal pipes
- Contact-free tracing of live lines through the receiver
- Torch
The cable detector consists of a transmitter and a receiver. Both devices are operated with a common 9 V
alkaline battery block. The device may only be operated with the specified batteries.
You can use as many as 7 cable detectors (transmitter and receiver) at the same time. The search sig-
nal is selective and can be encoded from 1 to 7.
The devices must not be operated when open, i.e. with an open battery compartment or when the bat-
tery compartment cover is missing. Live measuring in damp rooms or under unfavourable ambient con-
ditions is not permitted. Unfavourable ambient conditions are:
- Wetness or high air humidity
- Dust and flammable gases, vapours or solvent,
- Thunderstorms or similar conditions such as strong electrostatic fields etc.
For safety reasons, only use measuring cables or accessories which are adjusted to the specifications of
the multimeter when measuring.
Any use other than that described above damages the product. Moreover, this is linked to dangers such
as short circuits, fire, electric shock, etc. No part of the product may be modified or rebuilt!
Read the operating instructions carefully and keep them for later reference.
Always observe the safety instructions!

Scope of Delivery

Receiver LSG-10
Transmitter LSG-10B
2x 9V battery block
2 Safety measuring lines
2 Plug-on measuring probes
2 Safety alligator clips
Transport case
Operating instructions
29