Function principle
The cable detector consists of a transmitter and a
receiver. The transmitter generates a modulated current
signal that creates an electromagnetic field around a
connected conductor. This electromagnetic field is
detected and evaluated by the receiver.
In the receiver, three receiver coils are used in automa-
tic and manual mode. They enable position-indepen-
dent operation.
All parameters are indicated in the transmitter and
receiver display.
The receiver can be used as a contact-free voltage
detector and a torch independently of the transmitter. A
voltage test is only performed for grid alternate current.
The display can be lit for a short time if you are working in a badly lit environment.
Transmitter and receiver switch off automatically if they were not operated over an extended period of
time. This saves battery power and extends the period of operation. The cable detector can be used for
hobby or professional applications.

Measuring

Do not exceed the maximum permitted input values. Do not touch any circuits or
parts of circuits if there could be voltages higher than 50 V ACrms or 75 V DC present
within them. Danger to life!
Before measuring, check the connected measuring accessories for damage such as,
for example, cuts, cracks or squeezing. Never use defective measuring equipment!
Danger to life!
During measuring, do not grip beyond the tangible grip range markings present on
the test prods.
Measuring is only permitted when the battery and fuse compartment is closed.