After installation, please adjust material flow according to chapter 7.2.
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
9.6. Replacing the spindle of round/flat spray con-
trol
Steps: [11-1], [11-2], [11-3] [11-4]
It needs to be replaced when air leaks from the control knob or when the
flat/round control does not work. After disassembly, apply some sealant
on thread of the spindle, e.g. Loctite 242 [11-4].
10. Trouble-shooting
Malfunction
Fluttering/spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
Air bubbles appearing
in the gravity flow cup
Warning!
Cause
Fluid tip has not been
properly tightened
Air distribution ring is
damaged or clogged.
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the gravity flow
cup
Defective paint needle
sealing
Corrective Action
Tighten fluid tip [2-1]
with universal spanner
Replace air distribu-
tion ring, as it will be
damaged during disas-
sembly
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean nozzle set,
chapter 8, or replace,
respectively, chapter
9.1
Refill gravity flow cup
[1-6]
Replace the paint nee-
dle sealing, chapter
9.3