CWF menu
Access to
CWF shall be Off =
setup menu
no light in LED
No functions
3 strokes
chosen
Press the m/min button
Id
to gain access to the function
Device identification
If more than 1 CWF is used on the PI machine, each extra CWF
shall be given an ID number. As standard the CWF is set as number 1
Reset all user parameters.
CLr.
Settings made in the setup
menu are not affected
Optional extra functions.
Opt.
Valid for software version 2.0
Press the m/min key
m
to gain access to
min
the function
Turn potmeter.
Following functions
may be chosen:
Press the m/min key
PA.L.
to gain access
to the function
Panel lock function
Locks control panel except
inching and ON/OFF functions
Press the m/min key
U.AL.
to gain access
to the function
Unit Alarm
For running-in the CWF in the robot.
The power source will not register it
as an error if the CWF is placed in
OFF mode. The power source will
register function errors in the CWF
and stop the welding process.
Press the m/min key
PG.L.
to gain access
to the function
Program lock function
Locks programs P3-P10
Press the m/min key
trG.
to gain access
to the function
External start/stop of CWF
Possibility of
analogue trigger entry
16
Keep button down till
display shows 3 strokes
Setup menu is left by
pressing the m/min key
The display now shows
m
number of the CWF.
min
A figure between 1 & 8 is shown
To reset, press the m/min
and standby keys
The setup menu is left by
3 strokes
pressing the m/min key
Control panel locked.
No functions chosen
Inching and ON/OFF
functions can be used.
1
m
Display shows either of
min
the following messages
0
Factory setting
Lock function not used.
Operation mode.
All errors in the CWF are registered
and "Fdr" flashes in the PI display
if the power source is activated
1
Display shows either of
m
min
the following messages
0
Factory setting
The power source will not
register it as an error if the CWF
is placed in OFF mode
Programs
P3 - P10 locked
1
Display shows either of
m
min
the following messages
0
Factory setting
Lock function not used
Display shows
m
either of the
min
following messages
CWF is now in setup mode
and there are following options:
Turn potmeter.
.
Following functions may be chosen:
Display changes to
m
min
show m/min
To change the CWF number, press
and hold down the menu switch
whilst turning the potentiometer
Warning
2 CWF units must not have
the same number
Leave the setup menu,
m
and the display now
min
shows 1.00 m/min
m
min
To unlock, press and hold
down the menu switch
whilst turning
the potentiometer
To activate lock function,
press and hold down
the menu switch, whilst
turning the potentiometer
To disconnect error
registration function, press
and hold down the menu
switch whilst turning
the potentiometer
To connect error
registration function,
press and hold down
the menu switch whilst
turning the potentiometer
To unlock, press and hold
down the menu switch
whilst turning
the potentiometer
To activate lock function,
press and hold down
the menu switch whilst
turning the potentiometer
Factory setting
To change set-up, press
0
PI controls start/stop
and hold down the menu
switch, whilst turning
the potentiometer
Torch start/stop
1
Torch start/stop &
2
Torch reg.
PI controls
3
start/stop & Torch reg.
The display must show the
m
number given to the CWF.
min
Finish by pressing m/min
The computer
returns to setup mode
Display must
switch from 1 to
m
0. Finish by
min
pressing the
m/min key
Display must
switch from 0 to
m
1. Finish by
min
pressing the
m/min key
Display must
switch from 1 to
m
0. Finish by
min
pressing the
m/min key
Display must
switch from 0 to
m
1. Finish by
min
pressing the
m/min key
Display must
switch from 1 to
m
0. Finish by
min
pressing the
m/min key
Display must
switch from 0 to
m
1. Finish by
min
pressing the
m/min key
Display must
switch figure.
m
Finish by
min
pressing the
m/min key
Migatronic A/S
CWF menu
Arthur Nielsen
Rev: 7
15-02-2011
Page 1/2