Herunterladen Inhalt Inhalt Diese Seite drucken

Storage; Transport; Care And Maintenance; Maintenance Intervals - Kärcher HDS 2000 Super Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HDS 2000 Super:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Dump water
 Screw off water supply hose and high
pressure hose.
 Screw off supply hose at boiler bottom
and drain heating spiral empty.
 Operate device for max. 1 minute until
the pump and conduits are empty.
Flush device with anti-freeze agent
Note: Observe handling instructions of the
anti-freeze agent manufacturer.
 Fill anti-freeze agent of the trade into
swimmer container.
 Switch on appliance (without heater) till
the appliance has been completely
rinsed.
A certain corrosion protection is achieved
with this as well.
CAUTION
Risk of personal injury or damage! Consid-
er the weight of the appliance when storing
it.

Transport

ATTENTION
Protect the trigger from damage during
transport.
CAUTION
Risk of personal injury or damage! Mind the
weight of the appliance during transport.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Care and maintenance

DANGER
Risk of injury by inadvertent start-up of ap-
pliance and electric shock. Prior to all work
on the appliance, switch off the appliance
and pull the power plug.
 Shut off water supply.
 Open the hand spray gun.
 Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
 Close the hand spray gun.
 Set the appliance switch to "OFF".
28

Storage

 Pull main plug out of socket with dry
hands only.
 Remove water connection.
 Activate hand spray gun until device is
pressure less.
 Secure the trigger gun. To do so, push
the safety catch towards the front.
 Allow device to cool down.
Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.

Maintenance intervals

Every 500 operating hours, at least
annually
 Have the maintenance of the device
performed by the customer service.
Indicator lamp service will be
The service indicator lamp is lit up when
certain maintenance jobs are necessary on
account of reaching a certain number of op-
erating hours.
 Inform Customer Service.
Necessary maintenance jobs
– Check high pressure connections for
leaks.
– Clean fuel tank und fuel filter.
– Check pump for leaks.
– Change oil in the pump.
– Clean the sieve in the water connection
of both swimmer tanks.
– Clean sieve in front of the water short-
age safe guard.
– Remove the soot from the heating coil. *
– Decalcify the heating coil. *
– Clean/replace the ignition electrodes. *
– Clean/replace the burner nozzle. *
– Set the burner. *
– Check overflow valve of the pump for
leaks. *
– Check high pressure hose. *
– Clean hand-spray gun.
– Check pressure tank. *
* To be done by Customer Service.
– 9
EN
illuminated

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis