Fuel indicator lamp glows
Fuel tank empty
–
Refill.
Indicator lamp "Ready for use"
turns off
Engine overload/overheat
–
Turn device switch on "0" and let engine
cool off for min. 5 minutes.
If malfunction still occurs, have device
checked by customer service.
No line voltage, see "Appliance is not
running".
Indicator lamp liquid softener glows
Liquid softener tank is empty, due to
–
technical reasons a remainder stays in
the tank.
Refill.
Electrodes in the tank are dirty
–
Clean the electrodes.
Engine control lamp glows
Set the appliance switch to "0".
Allow device to cool down.
Set the appliance switch to "I".
Appliance is not running
No power
–
Check power connection/conduit.
Device is not building up pressure
Air within the system
–
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device
on and off multiple times with the device
switch.
Close and open the regulating spingle
(figure 9) with open hand spray gun.
Note: By dismantling the high pressure
hose from the high pressure connection the
venting process is accelerated.
If detergent tank is empty, refill.
Check connections and conduits.
Pressure is set to MIN
–
Set pressure to MAX.
Sieve in the water connection is dirty
–
Clean sieve.
Clean the fine filter; replace it, if neces-
sary.
Amount of water supply is too low.
–
Check water supply level (refer to tech-
nical data).
Device leaks, water drips from the
bottom of the device
Pump leaky
–
Note: 3 drops/minute are allowed.
With stronger leak, have device
checked by customer service.
Device turns on and off while hand
spray gun is closed
Leak in the high pressure system
–
Check high pressure system and con-
nections for tightness.
Device is not sucking in detergent
Leave device running with open deter-
gent dosage valve and closed water
supply, until the swimmer tank is
sucked empty and the pressure falls to
"0".
Open the water supply again.
If the pump still is not sucking in any deter-
gent, it could be because of the following
reasons:
Filter in the detergent suck hose dirty
–
Clean filter.
Backflow valve stuck
–
Figure 15
Remove the detergent hose and loosen
the backflow valve using a blunt object.
Burner does not start
Fuel tank empty
–
Refill.
Water shortage
–
Check water supply, check connec-
tions, clean water shortage safeguard.
Fuel filter dirty
–
Change fuel filter.
– 10
EN
33