Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Dimensions - clage CEX Serie Montageanleitung

E-kompaktdurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

3. Technical specifications

Model
Energy efficiency class
Rated capacity (Rated current)
Chosen capacity (Chosen current)
Electrical connection
Min. required cable size
Hot water (l/min)
max. at ∆t = 33 K
Rated volume
Type
Heating system
Required spec. water
resistance @ 15 °C
Spec. electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature choice
Water connection
Weight (when filled w. water)
VDE class of protection
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013
1) Mixed water
2) Flow rate limited to achieve optimum temperature rise
3) Without flow regulator

4. Dimensions

11 kW (16 A)
1,5 mm
100
177
CEX ELECTRONIC MPS ®
A *
)
11 / 13,5 kW (16 / 19,5 A)
3~ / PE 380..415 V AC
2
4,8
0,3 l
Pressure type 1.0 MPa (10 bar)
bare wire heating system IES ®
≥ 1000 Ωcm
≤ 100 mS/m
≤ 70 °C
2,0 – 5,0 l/min
0,2 bar at 2,5 l/min
1,3 bar at 9,0 l/min
20 °C – 60 °C
G ½"
2,7 kg
I
IP25
Dimensions in mm
17
13,5 kW (19,5 A)
2,5 mm
2
5,8
1)
2)
3)
CLAGE
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis