Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Wiring Diagram; Structural Prerequisites; Load Shedding Relay - clage CEX Serie Montageanleitung

E-kompaktdurchlauferhitzer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
CEX ELECTRONIC MPS ®

7. Electrical connection

Wiring diagram

EN
2
1
1. Electronic circuitry
2. Heating element
3. Safety pressure cut-out
4. Terminal strip
5. Safety thermal cut-out
Only by a specialist!
Please observe:
• VDE 0100
• The installation must comply with current IEC and national local regulations or
5
any particular regulations, specified by the local electricity supply company
• The rating plate and technical specifications
• The unit must be earthed!
3

Structural prerequisites

4
• The appliance must be installed via a permanent connection. Heater must be
earthed! A maximum cable size must be observed: 6 mm
• The electric wiring should not be injured. After mounting, the wiring must not be
direct accessible.
• An all-pole disconnecting device (e.g. via fuses) with a contact opening width of at
least 3 mm per pole should be provided at the installation end.
• To protect the appliance, a fuse element must be fitted with a tripping current com-
mensurate with the nominal current of the appliance.

Load shedding relay

If further three-phase appliances are connected, we recommend the use of a CLAGE
load shedding relay (art. no.
A special operating mode must be selec ted on the appliance for this purpose.
LCD Description
0
Operation without load shedding, manufacturer's setting
1
Operation with normal load shedding relay
2
Operation with sensitive load shedding relay
To change the operating mode, press the three keys
and wait until the desired mode (0, 1 or 2) is shown on the display, then release the
keys. Operating mode 1 must be selected first, thus to check the correct operation of
the load shedding relay at low appliance output (35 degree setpoint and low water
flow rate). Mode 2 must be selected if the load shedding relay flickers.
Electrical connection
Check that the power supply is switched off prior to electrical connection!

Electrical connection with pre-installed power cable

The appliance is to be connected with the pre-installed power cable to a terminal box.
If necessary, use one of the three predetermined breaking points for the cable entry (at
the right, left or top).
20
82250).
The relay can be connected to phase conductor L
,
2
.
.
2
,
and
simul taneously

Werbung

Inhaltsverzeichnis
loading