TÜV NORD CERT GmbH & Co. KG
Am TÜV 1
D-30519 Hannover
Annexe to IECEx TUN 04.0015X
Page 3 of 3
Electrical data for type TZIDC, TZIDC-110 resp. TZIDC-120 with marking Ex nA II T6
Type TZIDC resp. TZIDC-200
Signal circuit
(terminals 11(+), 12(-))
Switch input
(terminals 81(+), 82(-))
Switch output
(terminals 83(+), 84(-))
Optionally the following modules are allowed to be used with type TZIDC:
Digital feedback
(terminals +51, -52
resp. +41, -42))
Analogue feedback
(terminals +31, -32)
Type TZIDC-110
Input circuit
(terminals +11, -12)
Type TZIDC-120
Input circuit
(terminals +11, -12)
Additionally the following modules are allowed to be used with all types marked Ex nA II T6:
Shutdown-switch-input
(terminals +51, -52
resp. +85, -86)
Mechanical digital feedback
(terminals Limit1 +51, -52
resp. Limit2 +41, -42)
42/18-80 DE
U = 8.7 VDC; 4...20 mA, max. 21.5 mA
U = 12...24 VDC; 4 mA
U = 11 VDC
U = 5...11 VDC
U = 10...30 VDC; 4...20 mA, max. 21.5 mA
U = 9..32 VDC; 10.5 mA
U = 9..32 VDC; 11.5 mA
U = 20...30 VDC
U = 5...11 VDC