Installation instructions

Dear Customer,
been manufactured,
tested and packed with
Congratulations on pur-
the greatest care.
chasing this STEINEL Inf-
Please familiarise yourself
rared Sensor and thank
with these instructions
you for the confidence
before attempting to in-
you have shown in us.
stall the sensor since
You have chosen a high-
prolonged reliable and
quality product that has
Principle
The integrated pyroelectric
With a detection angle of
infrared detector senses the
160° and a max. reach of
invisible heat radiated from
12 m the sensor watches
moving objects (people, ani-
over an area of approx.
mals, etc.). The heat detect-
165 m
. If you only wish to
2
ed is electronically converted
cover a smaller area, reach
into a signal that switches on
may be reduced by tilting
loads (e.g. a light) connected
the sensor unit. Using the
to it. Heat is not detected
swivel mount supplied, the
through obstacles, such as
sensor unit can also be
walls or panes of glass. Heat
turned horizontally, making
radiation of this type will,
it possible to target the
therefore, not trigger the
detection zone exactly as
sensor.
you choose. The detection

Safety warnings

Installation of the sensor
Disconnect the power
involves work on the
before attempting any
mains power supply. This
work on the motion
work must therefore be
detector.
carried out professionally
The electrical connection
in accordance with the
lead must be dead during
applicable wiring regu-
installation. Therefore,
lations and electrical
switch off the power first
operating conditions.
and use a voltage tester
(
- VDE 0100,
to check that the power
D
- ÖVE-EN 1,
supply is disconnected.
A
- SEV 1000).
12
trouble-free operation will
only be ensured if it is
installed properly.
We hope your new Infrared
Sensor will give you lasting
satisfaction.
(s. fig. page 2)
angle can also be adjusted to
suit individual requirements
by fitting shrouds.
Important: the safest motion
detection is obtained when
the device is mounted and
aligned laterally to the walk-
ing direction and no obsta-
cles (such as trees and walls,
for example) obstruct the
view.
Please note that the sen-
sor must be protected
by a 10 A circuit breaker.
The mains supply lead
must be no greater than
10 mm in diameter.
Installation
The site of installation should
Note: For surface-mounted
be at least 50 cm from a light
wiring, it is recommended to
because heat radiated from it
install the swivel mount 
may trigger the sensor unin-
(see below).
tentionally. To obtain the
Alternatively, the unit may be
specified reach of 12 m, the
pierced at the thinner section
sensor should be installed at
to pass the cable through.
5. Screw mounting plate 
a height of approx. 2 m.
Please observe the safety
to wall.
warnings on page 12.
6a) Connecting the mains
Installation procedure:
lead
1. Undo screws on hous-ing
The mains lead consists of a
 2. Do not detach wiring
2-3 phase cable
L
from terminal block, but
= phase conductor
gently pull entire terminal
N
= neutral conductor
assembly, including sensor
PE = protective-earth
unit  (cylindrical section),
conductor
to remove it. 3. Hold mount-
ing plate  against wall/ceil-
If you are in any doubt, you
ing, mark drill holes, paying
must identify the cables using
attention to wiring runs con-
a voltage tester; then discon-
cealed in wall/ceiling. Drill
nect the power supply again.
holes, insert wall plugs
The phase (L) and neutral
(6 mm). 4. Break open pre-
conductor (N) are connected
punched cable entry holes as
according to terminal assign-
appropriate for concealed 
ment. The protective-earth
or surface-mounted  instal-
conductor is connected to
lation, insert grommets,
the earth terminal
pierce and pass cable
A mains switch for 'ON' and
through.
'OFF' switching can of
course be installed in the
mains lead.
Installation with swivel mount
The swivel mount  allows
2. Hold swivel mount 
you to turn the motion detec-
against wall and mark
tor horizontally. This provides
drill holes, drill the holes,
additional adjustment for the
insert wall plugs, pass cable
detection zone.
through. Connect as
1. Press cupped pieces  out
described in „Installation".
of swivel mount  provided
3. Pass screws through
with sensor unit.
cupped pieces  and secure
(s. fig. page 3)
6b) Connecting the load
supply lead
The load supply lead (e.g.
light) is also a 2 to 3-core
cable which is connected to
terminals N and L'. The live
conductor must be connect-
ed to the terminal marked L'.
Connect the neutral conduc-
tor to the terminal marked N
together with the neutral con-
ductor of the mains power
supply lead. The protective-
earth conductor is connected
to the earth terminal
.
7. Once wiring is completed,
insert terminal block together
with sensor unit  into
mounting plate , fit housing
cover  and secure in place
with fastening screws.
.
swivel mount  in such a
way that the screw head is
positioned on the smooth
side and the domed side
rests against the mounting
plate  (see diagram).
13