Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions - STEINEL sensIQ S Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation instructions

GB
Dear Customer,
Congratulations on purchasing your new
STEINEL Infrared Sensor and thank you for the
confidence you have shown in us. You have
chosen a pioneering product that has been
manufactured, tested and packed with the
greatest care.
Principle
The unit is equipped with pyro sensors that
detect the invisible heat emitted from moving
objects (people, animals etc.). The heat thus
detected is electronically converted and
switches ON connected consumers (e.g.
Safety warnings
During installation, the electrical wiring you
are connecting must be dead. Therefore,
switch off the power first and use a voltage
tester to check that the power supply is
disconnected.
Installing the sensor involves work on
the mains power supply. This work must
therefore be carried out professionally in
Installation
The site of installation should be at least 50 cm
away from another light because heat radiated
from it may activate the system.
In order to achieve optimum detection, the
sensor must be installed tangentially to the
walking direction.
An optional corner wall mount is available for
installing the sensor on external corners.
(see Accessories on p. 11).
The mains supply lead is a 3-core cable
(max. conductor Ø 15 – 19 mm):
L
= phase (usually black, brown or grey)
N
= neutral conductor
PE = protective-earth conductor
System components
Surface-mounting adapter
Sealing plug
Film shroud
Lens enclosure
Condensation water drainage hole
Wall mount / sensor unit
Corner wall mount (optional)
Please familiarise yourself with these instruc-
tions before attempting to install the sensor
light because prolonged reliable and trouble-
free operation will only be ensured if it is fitted
properly.
We hope your new Infrared Sensor will give you
lasting satisfaction.
a light). No heat radiation is detected through
obstacles such as walls or panes of glass
for example and consequently no switching
occurs.
accordance with applicable national wiring
regulations and electrical operating condi-
tions. ( D -VDE 0100, A -ÖVE/ÖNORM E
8001-1,
-SEV 1000)
Only use genuine replacement parts.
Repairs may only be carried out by special-
ist workshops.
If the rubber seal is damaged, the cable entry
openings must be sealed with an M 16 or M 20
double seal cable gland.
A condensation water drainage hole is outlined
in the housing. This can be opened for wall
installation.
Wall mount
must be renewed if any subse-
quent change is made to wiring run.
Plug-in terminals
Locking screw
Light-level setting
Time setting
Reach setting
I
Mains connection, concealed wiring
II
Mains connection, surface wiring
- 12 -
Connection examples
I
Light without existing neutral conductor
II
Light fitted with a neutral conductor
III Connection by means of two-circuit
single-interruption switch for manual
and automatic operation
IV Connection by means of two-way switch
for manual override and automatic
operation
Setting I: Automatic operation
Position II: Manual operation
Light ON permanently
Note: The system cannot be switched OFF,
it is only possible to select operation at
setting I or II.
Technical specifications
Dimensions (H x W x D):
74 x 114 x 128 mm
Output:
Incandescent lamps, 2000 W max. at 230 V *
Incandescent lamps, 1200 W max. at 120 V *
Fluorescent tube, 1000 VA max. at 230 V (cos ϕ = 0.5)
Fluorescent tube, 500 VA max. at 120 V (cos ϕ = 0.5)
Max. starting current
800 A / 200 µs max.
Electronic ballast *
30 x (1 x 18 W), 25 x (2 x18 W)
25 x (1 x 36 W), 15 x ( 2 x 36 W)
20 x (1 x 58 W), 10 x (2 x 58 W)
Power supply:
100 - 240 V AC 50/60 Hz
Angle of coverage:
300° with 180° angle of aperture, as well as sneak-by guard
for coverage directly below the sensor. Capability of masking
out individual segments
Reach:
Adjustable in 3 directions independently from one another by
control dial, (2 – 20 m max., temperature-stabilised)
Sensor technology:
4 sensors, 6 levels for long-distance detection and
5 for sneak-by guard, 1360 switching zones
Time setting:
5 sec. – 15 min., pulse mode (approx. 2 sec.)
Twilight setting:
2 – 2000 lux
Manual override:
selectable (4 hrs.) / (by remote control only)
Permanently OFF:
selectable (6 hrs.) / (by remote control only)
IP rating
IP 54 through 2-component injection mould technology
Temperature range:
- 20 °C to + 50 °C
*1)
VDE-tested
*2)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
a) Loads, lighting of 2000 W max.
(see Technical specifications)
b) Sensor connection terminals
c) Indoor switch
d) Indoor series switch, manual, automatic
e) Indoor two-way switch, automatic
operation, manual override
1)
1)
2)
:
- 13 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis