Installation instructions

GB
Dear customer,
Thank you for the confi-
Please familiarise yourself
dence that you have placed
with these instructions
in us in purchasing your
before installation, since
new STEINEL infrared sen-
only correct and commis-
sor. You have decided on a
sioning guarantees long,
high quality product, manu-
reliable and trouble-free
factured, tested and pack-
operation.
ed with the greatest care.

Appliance description

Safety screw
Twilight setting
2–2000 lux
Decorative cover
Time setting
Lens (removable and
10 sec.–15 min.
rotatable to select the
reach – basic setting of
max. 5 m or 12 m

Technical specifications

Dimensions:
(H x W x D) 120 x 76 x 56 mm
Output:
max. 1000 W (ohmic load, e.g. filament bulb)
max. 1500 W (uncorrected, inductive, cos ϕ = 0.5,
max. 1600 W (electronic ballasts, capacitive;
Connection:
230–240 V, 50 Hz
Angle of coverage:
180° horizontal, 90° vertical
Sensor reach:
basic setting 1: max. 5 m
basic setting 2: max. 12 m
+ fine adjustment with shrouds: 1–12 m
Time setting:
10 sec.–15 min.
Twilight setting:
2–2000 lux
Enclosure:
IP 54
12
We hope you enjoy your
new usage appliance.
Catch (housing can be
swung open for installa-
tion and power supply
connection)
e.g. fluorescent lamps)
e.g. energy-saving lights, max. 8)
Principle
The detector is equipped
No heat radiation is detect-
with two 120° pyro sensors
ed through obstacles, such
which detect the invisible
as walls or glass and no
infrared heat emitted by
switching therefore occurs.
moving objects (pedes-
With the aid of the two pyro
trians, animals, etc.). The
sensors, a detection angle
heat thus detected is elec-
of 180° (with an opening
tronically converted and
angle of 90°) is achieved.
switches on connected
The lens is removable and
consumers (e.g. a light).
can be rotated. This allows
Max. reach 12 m
Max. reach 5 m
ca.12m
Walking direction: frontal
Walking direction: diagonal
Safety notification
Disconnect the power
Installation of the sensor
supply before any work
involves work on the
on the motion detector!
mains power supply; this
During installation, the
work must therefore be
electric power cable to
carried out professionally
be connected must be
in accordance with regu-
voltage-free. There-
lations.
fore, switch off the power
Please note that the
first and check freedom
sensor must be protected
from voltage with a
by a 10 A circuit breaker.
voltage tester.
The mains supply lead
two basic reach settings of
max. 5 m or 12 m. The
infrared sensor can be
installed without difficulty
on inside and outside cor-
ners using the enclosed
wall mounts.
Important: The most reli-
able motion detection is
achieved by mounting the
unit diagonally to the direc-
tion of movement and en-
suring that no obstacles
(such as trees or walls)
obstruct the line of sight.
must be no greater than
10 mm in diameter.
Perform time and twilight
adjustment only with the
lens installed.