Functions
The system can be put into
has been connected and
operation once the sensor
installed. Two setting controls
Switch-off delay
(time setting)
The chosen light 'ON' time
can be varied continuously
from approx. 8 sec. to a
maximum of 35 min. The
shortest period, approx.
8 sec., is selected by
turning the control fully
8 sec. – 35 min.
clockwise. The longest
period, approx. 35 mins.
Twilight setting
(response threshold)
The chosen detector
response threshold can
be adjusted continuously
from approx. 2 lux to 2000
lux. Turning the control
fully clockwise will select
daytime operation at
approx. 2000 lux.
2 – 2000 lux
Reach adjustment
Reach can be reduced by
horizontally through 40° (only
tilting (70°) the sensor.
with swivel mount) to align
The sensor can be turned
the detection zone in exactly
Precision adjustment using shrouds
The adhesive shrouds
angle to suit individual
provided may be used to
requirements. This makes
adjust the sensor's detection
it possible, for example,
14
are provided on the bottom
of the unit.
is selected by turning the
control fully anticlockwise.
It is recommended to select
the shortest time for adjust-
ing the detection zone and
for performing the walk test.
Any movement in the detec-
tion zone will reactivate the
time setting.
Turned fully anti-clock-wise,
the control is set to dusk-to-
dawn operation at approx.
2 lux. When adjusting the
detection zone and for the
performance test in daylight,
the adjusting screw must be
turned fully clockwise.
(s. fig. page 4)
the way you require.
(s. fig. page 4)
to blank out neighbouring
premises from detection or
specifically target paths.

Wiring examples

1. Light without neutral conductor
3. Connection using series switch for
manual and automatic operation
1) e.g. 1-4 x 100 W filament bulbs
2) Service load, light of 600 W max. (see Technical specifications)
3) IS 2160 connection terminals
4) Indoor switch
5) Indoor series switch, manual, automatic
6) Indoor double-throw switch, automatic, permanent light 'ON'
Operation/Maintenance
The Infrared Sensor is
pose. Weather conditions
suitable for switching light
may affect the way the
'ON' and 'OFF' automatically.
motion detector works.
The unit is not suitable for
Strong gusts of wind, snow,
special burglary alarm
rain or hail may cause the
systems since it lacks
light to come 'on' when it is
the tampering protection
not wanted because the
prescribed for this pur-
sensor is unable to distin-
2. Light with neutral conductor
4. Connection to double-throw switch
for permanent light 'ON' and automatic
operation
Setting I: automatic operation
Setting II: manual operation for permanent
light 'ON'
Important: the unit cannot be switched off, but
operated only at settings I and II.
guish sudden changes of
temperature from sources of
heat. The detector lens may
be cleaned with a damp cloth
if it gets dirty (do not use
cleaning agents).
15