Technical specifications

Dimensions:
(H x W x D) 113 x 78 x 73 mm
Output:
Incandescent lamps, 600 W max. at 230 V AC
Fluorescent tube, 500 W max.
at cos ϕ = 0.5, inductive load at 230 V AC
4 x 58 W max., C ≤ 88 µF
at 230 V AC
Connection:
230 – 240 V, 50 Hz
terminal block suitable for following supply leads:
3-core Ø 1.5 or 2.5 mm
Angle of coverage:
160° with sneak-by guard
Pivoting range:
40° horizontal, 70° vertical
Reach:
12 m max.
Light threshold:
2 – 2000 lux
Time setting:
8 sec. – 35 min. (factory setting: 10 sec.)
Light threshold:
2 – 2000 lux (factory setting: 2000 lux)
Enclosure:
IP 54
Temperature range:
-20 °C to +50 °C
*1)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).

Troubleshooting

Malfunction
Cause
Without power
Fuse blown, not switched
'ON'
Short circuit
Does not switch 'ON'
Twilight setting in
nighttime mode during
daytime operation
Bulb blown
Mains switch 'OFF'
Fuse blown
Detection zone not
properly targeted
16
*1)
or 5-core Ø 1.5 mm
2
2
Remedy
Renew fuse, switch 'ON'
mains power switch,
check wiring with voltage
tester
Check connections
Readjust
Replace bulb
Switch 'ON'
Renew fuse, check
connection if necessary
Re-adjust
Malfunction
Cause
Does not switch 'OFF'
Continued movement in
detection zone
Light is in detection zone
and keeps switching on
as a result of temperature
change
Set to continuous
operation by indoor
series switch
Keeps switching 'ON'/'OFF'
Light is in detection zone
Animals moving in
detection zone
Switches 'ON' when it
Wind is moving trees and
should not
bushes in the detection
zone
Cars in the street are
being detected
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans or
open windows
Reach modification
Change in ambient
temperatures
Remedy
Check detection
zone and re-adjust if
necessary or fit shrouds
Readjust zone
Set series switch to auto-
matic mode
Change zone, increase
distance, reduce output
Tilt sensor higher or
apply specific shrouds,
adjust detection zone or
fit shrouds
Adjust detection zone or
fit shrouds
Change detection zone,
tilt sensor down
Adjust detection zone or
change site of installation
When it is cold, shorten
reach by tilting sensor
down
When it is hot, tilt sensor
up
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis