Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

11 Troubleshooting

When the PV system does not operate normally, we recommend the following
solutions for quick troubleshooting. If an error occurs, the red LED is lit.
The corresponding causes are described in section 9.2 "Display messages".
The corresponding corrective measures are as follows:
Object
Error code
38
36
Resumable
Fault
6
37
41,42,43,44,
45
54
Corrective measures
•Check the PV array's insulation to ground, make sure
that the insulation resistance to ground is greater than
1MOhm; Otherwise, make a visual inspection of all PV
cables and modules.
•Make sure the ground connection of the inverter is
reliable.
If this fault is still shown, please contact service.
•Make sure the ground connection of the inverter is
reliable.
•Make a visual inspection of all PV cables and modules.
If this fault is still shown, please contact service.
•Check the open-circuit voltages of the strings, make
sure it is lower than the Max. DC input voltage of the
inverter;
If the input voltage lies within the permitted range, and
the fault still occurs, maybe the internal circuit has
broken, please contact service.
•Check the open-circuit voltages of the strings, make
sure it is lower than the Max. DC input voltage of the
inverter.
If the input voltage lies within the permitted range and
the fault still occurs, please contact service.
•Disconnect the inverter from the grid and the PV array,
reconnect them after 3 minutes.
If this fault is still being shown, please contact service.