10.6 Power reduction

In order to ensure inverter operation under safe conditions in terms of the ambient
temperature and input voltage, the device automatically decreases power output.
Apart from the ambient temperature and the input voltage, power reduction depends
on many operating parameters, such as grid voltage, grid frequency and power
available from the PV modules. This device can decrease its power output during
certain periods of the day according to these parameters.
4000
3000
2000
1000
0
25 30 35 40 45 50 55 60 65 70 75 80
Power reduction with increased ambient temperature (TL3680)
Power reduction with increased ambient temperature (TL5000-10)
Installation and Operating Instructions
Ambient temperature[℃]
360V
250V
520V