10.2 AC output data
Type
Power connection
Rated output power
Max. output apparent power
Rated grid voltage, frequency
(1)
AC voltage range
Operating range at AC mains
(2)
frequency 50 Hz
Operating range at AC mains
(2)
frequency 60 Hz
Rated output current at 220V
Rated output current at 230V
Rated output current at 240V
Max. continuous output current
Power
VDE-AR-N 4105
factor
Other safety
Harmonic distortion (THD) at Pac,r
Night-time power loss
Standby power loss
(1) The AC voltage range depends on the local safety standards.
(2) The AC frequency range depends on the local safety standards.
(3) At country configuration, rated output power 4600 VA.
48
TL3680
Single-phase
4600W(Germany & Australia)/
3680 W
4600VA(Germany & Australia)/
3680 VA
220 V/230 V/240 V, 50 Hz/60 Hz
180 V to 280 V
45 Hz to 55 Hz
55 Hz to 65 Hz
16 A
16 A
15.3 A
16 A
0.95 (lagging) to 0.95 (leading)
>0.97 at 20% load, >0.99 at 100% load
Installation and Operating Instructions
TL5000-10
5000W(others)
5000VA(others)
(3)
20.9 A
/ 22.7 A
(3)
20 A
/ 21.7A
(3)
19.2 A
/ 20.8 A
25 A
< 3%
< 1 W
< 6 W