8 Disconnecting the inverter from voltage sources

Before performing any work on the inverter, disconnect it from all voltage sources as
described in this section. Always adhere strictly to the given sequence.
1. Disconnect the miniature circuit breaker and secure against reconnection.
2. Disconnect the DC-switch and secure against reconnection.
3. Use a current probe to ensure that no current is present in the DC cables.
4. Release and disconnect all DC connectors. To do so, insert a flat-blade
screwdriver or an angled screwdriver (blade width: 3.5 mm) into one of the side slits
and pull the DC connectors straight out. Do not pull on the cable.
5. Release and disconnect the AC connector. To do so, insert a flat-blade
screwdriver (blade width: 3.5 mm) onto the spring clamp and pull the AC coupling
plug out of the AC connection receptacle on the inverter. Do not pull on the AC cable.
6. Wait until the all LEDs and the display have gone out.
DANGER!
Danger to life due to high voltages!
The capacitors in the inverter take 5 minutes to discharge.
• Wait 5 minutes before opening the inverter.