USE THE FUNCTION "CUSTOM CARRIER"
After the local oscillator has been set, the desired carrier frequency can be selected.
Note: The selected local oscillator determines the available frequency range.
OPERATING MENU
First use the UP and DOWN buttons to select your local oscillator.
There are various local oscillators available, some of which also
have a 22 kHz tone available. The local oscillators are listed in
the table below.
When you have made your selection, press the RIGHT button to
set the transponder frequency.
(The menu shown here is just for explanation; it is not visible in
this form).
To set the desired frequency, use the UP and DOWN buttons
to change the highlighted fi gure. Pressing the LEFT or RIGHT
button switches to the next number. When the desired frequency
has been reached, press the RIGHT button to switch to the
"Symbol rate" screen. Take care not to select values outside the
valid range (e.g. 20700 MHz in Ku band mode).
The symbol rate is set as for setting the frequency for the
desired signal. Use the LEFT and RIGHT buttons to highlight
the desired number and use the UP and DOWN buttons to
change the value. Symbol rates can be set to values between
"01000" and "45000". When the desired symbol rate has been
reached, press the RIGHT button to switch to the "FEC" screen.
This screen allows you to select the desired FEC. If
the FEC is not known, select "Any". The MSK 115 will
test all FEC settings during the search after "Enter
carrier". The available FECs are listed in the table
on the right. Press the RIGHT button to switch to the
"LNB Voltage" screen.