8.9
Thermal protector
The thermal protector is built into the device.
If the thermal protector has tripped, proceed as follows:
• Pull out the mains plug.
• Wait about two to three minutes.
• Plug the device in again.
• If the device does not start, repeat the process.
• If the device does not start again, switch the device
off and on again using the on/off switch (16).
• If you have carried out all of the steps above and the
device still does not work, contact our service team.
9.
Electrical connection
The connection complies with the applicable national
regulations.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
• Before commissioning, ensure that the mains volt-
age matches with the operating voltage on the type
plate.
• When using extension cables, please follow the
manufacturer's instructions.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Information:
This product is equipped with a powerful motor (contin-
uous operation 2200W)!
This can lead to the fact that your circuit breaker in the
fuse box activates as soon as you start the product.
The reason is different manufacturers of circuit break-
ers (automatic circuit breakers) show different toleranc-
es for the switch-off characteristics. We recommend a
fuse protection of C16A for this product.
If this problem occurs, please use an extension cable
with a length of at least 10-20 metres, connecting it be-
tween the socket and product.
9.1
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
socket.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnect-
ed from electrical power when checking for damage.
Electrical connection cables must comply with nation-
al provisions. Only use connection cables of the same
designation.
The printing of the type designation on the connection
cable is mandatory.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
10. Cleaning, maintenance and storage
m Attention!
Pull out the mains plug before carrying out any clean-
ing or maintenance work! Danger of injury due to elec-
tric shocks!
m Attention!
Wait until the device has cooled down completely!
Danger of burning!
m Attention!
Depressurise the device before carrying out any
cleaning or maintenance work! Danger of injury!
10.1 Cleaning
• Keep the device as free of dust and dirt as possible.
Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
www.scheppach.com