• The oil level in the compressor pump must be
checked before commissioning.
• The compressor may only be used outdoor briefly
when the ambient conditions are dry.
• The compressor must always be kept dry and must
not be left outdoors after work is complete.

8. Assembly and operation

Attention!
Always make sure the device is fully assembled before
commissioning!
You require the following for assembly:
• 2 x open-ended spanner 17 mm (not included in the
scope of delivery)
• 2 x open-ended spanner 14 mm (not included in the
scope of delivery)
8.1
Fitting the wheels (fig. 5)
• Fit the wheels (11) provided as shown.
8.2
Mounting the foot (2x) (Fig. 6)
• Fit the foot (2x) provided as shown in.
8.3
Installing the air filter (2x) (Fig. 7, 8)
• Remove the transport plug (A) and screw the air
filter (14) to the device.
8.4
Replacing the transport lid (B) (Fig. 9, 10)
• Remove the transport cap (B) of the oil filling open-
ing (18).
• Fill the compressor oil supplied into the compressor
pump housing and fit the enclosed oil plug (15) into
the oil filling opening (15).
8.5
Mains power connection
• The compressor is equipped with a mains cable with
an earthed plug. This can be connected to any 230
V
50 Hz protective contact socket, with fuse pro-
tection of at least 16 A.
• Before commissioning, ensure that the mains volt-
age matches with the operating voltage and the ma-
chine's power rating on the type plate.
• Long supply lines, as well as extensions, cable
drums etc. cause voltage drop and can prevent the
motor from starting.
• At low temperatures below +5 °C, sluggishness may
make starting difficult or impossible.
8.6
On/Off switch (Fig. 2)
• Pull the On/off switch (16) upwards to switch on
the compressor. Press the ON/OFF switch down
to switch off.
8.7
Adjusting the pressure: (Fig. 1, 3)
• The pressure at the manometer (4) is adjusted with
the pressure regulator (5).
• The pressure set can be drawn from the quick cou-
pling (3).
• The vessel pressure can be read off at the pres-
sure gauge (6).
• The vessel pressure is taken at the quick-coupling (7).
8.8
Setting the pressure switch (fig. 1)
• The pressure switch (2) is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
8.9
Thermal protector
The thermal protector is built into the device.
If the thermal protector has tripped, proceed as follows:
• Pull out the mains plug.
• Wait about two to three minutes.
• Plug the device in again.
• If the device does not start, repeat the process.
• If the device does not start again, switch the device
off and on again using the on/off switch (16).
• If you have carried out all of the steps above and the
device still does not work, contact our service team.
9.

Electrical connection

The connection complies with the applicable national
regulations.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
• Before commissioning, ensure that the mains volt-
age matches with the operating voltage on the type
plate.
• When using extension cables, please follow the
manufacturer's instructions.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Information:
This product is equipped with a powerful motor (contin-
uous operation 2200 W)!