Installation instructions

Before the installation of the various groups (taps or shower) make
sure the pipe-line is clean of any impurity which might damage them.
Hydraulic
Connect the water heater's inlet and outlet with pipes or fittings that are
connection
resistant to the working pressure as well as to the temperature of the hot
water that can usually reach and exceed 80° C. We therefore advise
against the use of materiales that do not resist such high temperatures.
Screw to the entry-pipe (marked by a blue ring) the safety valve, supplied
with the apparatus, and connect this to the water feeding pipe. The safety
valve can be damaged because of exessive tightening. The safety valve
has a calibration value of about 80 N/cm
phase is quite normal; for this reason it is advisable to connect the valve
to a little drain-pipe. In case of pressure on the network close to ,e
calibration-values of the valve, it is needed to apply a pressure-reducer
as far as possible from the boiler.
To use a service valve on the mains water pipe.
"Open
For this type of installation it is needed to utilise suitable watertaps and
outlet"
carry out the connection as shown in the scheme see "open outlet
connection
connection". With this solution the water-heater can operate at any network
pressure. The safety valve is not to be fitted.
Electrical
The feeding cable is to be inserted in the proper hole situated in the back
connection
of the apparatus and slide it until it reaches the housing slot near the
thermostat.
The electric connection is carried out directly to the clamps of the thermostat.
To disconnect the unit from the network use a bipolar, switch conform to
IEC standards (contact opening at least 3 mm., better if equipped with
fuses).
The appliance must be earthed and the earth cable (which must be yellow-
green ain colour) is fixed to the terminal marked by the symbol
Before starting it working, make sure that the network tension is in
compliance with the rated values of the apparatus.
If the feeding cable isn't supplied with the water heater to connect
the appliance to thermostat clamps directly.
The lasta operation before connectin the voltage is to fill the boiler with
Starting
water from the mains. Open the main water supply cock and the hot water
und testing
tap to let all the air out of the boiler. Make a sight check for water leaks;
make sure the surge tank flange is centered; if necessary, tighten the nut
gently and then connect the voltage.
Instruction for use
Working
The war ning light remains on only during heating phase.
The thermostat will automatically disconnect the heating element when
the selected operating temperature is reached.
2
. A slight drip during the heating
GB
.
8