If the distances between
6.
Screw the sealing cover and decorative cover back on.
7.
Close the rubber seals.
Note: We recommend using shielded twisted pair cables with AWG24 to AWG16 conductors for
RS-485 communication.
If the total length of all cables exceeds 200 metres, terminating resistors should be used. To do this,
move the jumper on the circuit board from A-B to B-C for the first and last stations.
No liability is accepted for damage caused by incorrect operation.
If you require technical assistance, please contact our support team via our website www.EM2GO.de.
6. Operation
6.1. Switching on
Once the charging station has been properly installed and the power supply switched on, the charging station
will switch to standby mode.
6.1.1. LED strip
The LED strip indicates the status of the charging station.
50
1
A
2
B
3
C
Fig. 5-9 RS485 cable connection
LED strip
Meaning
Off
Switched off
White
Standby
Blue
EV connected
Yellow
Swipe RFID card
Light blue
Charging