Herunterladen Diese Seite drucken

Whirlpool PACW9COL Gebrauchsanweisung Seite 29

Vorschau ausblenden Andere Handbücher für PACW9COL:
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
TROUBLESHOOTING
Before calling for service, try the suggestions below to see whether you can solve your
problem without outside help.
Trouble
• The power supply cord is unplugged. Plug into a grounded outlet. See "Electrical
• A household fuse has blown, or a circuit breaker has tripped. Replace the fuse, or
Air conditioner does
• The On/Off button has not been pressed. Press ON/OFF.
not operate
• The local power has failed. Wait for power to be restored.
• Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace
• Too many appliances are being used on the same circuit. Unplug or relocate
Air conditioner
• You are trying to restart the air conditioner too soon after turning off air
blows fuses or trips
circuit breakers
• You have changed modes. Wait at least 3 minutes after turning off air conditioner
• Is there a door or window open? Keep doors and windows closed.
• In cooling mode: the air conditioner is in a heavily occupied room, or heat
Air conditioner
seems to run too
much
• In heating mode: the air conditioner is in a very cool room. Local air conditioners
Air conditioner runs
for a short time
• Set temperature is close to room temperature. Lower or Higher set
only, but room is
not cool or hot
• If the unit display error code E5, it is water full in the unit, you should drain the
Display error code
• If the unit display error code E1/E2/E3/E6/E7/EA, please contact customer service.
• The filter is dirty or obstructed by debris. Clean the filter.
Air conditioner runs,
• Air outlet is blocked. Clear air outlet.
but does not
• The setting temperature is not compatible. In cooling mode: set temperature is
cool/hot
• The air conditioner is not properly sized for your room. Check the
• The filter is dirty or obstructed by debris. Clean the filter.
• In cooling mode there is excessive heat or moisture (open container cooking,
Air conditioner
cycles on and off too
much
• The louvers are blocked. Install the air conditioner in a location where the
• The outside temperature is below 18°C. Do not try to operate your air
Requirements."
reset the circuit breaker. See "Electrical Requirements."
with a time-delay fuse or circuit breaker of the correct capacity. See "Electrical
Requirements."
appliances that share the same circuit.
conditioner. Wait at least 3 minutes after turning off air conditioner before trying
to restart it.
before trying to restart the appliance.
producing appliances are in use in the room. Use exhaust vent fans while cooking
or bathing and try not to use heat producing appliances during the hottest part of
the day. Local air conditioners are designed as supplemental cooling to local areas
within a room. A higher capacity air conditioner may be required, depending on
the size of the room being cooled.
are designed as supplemental heating to local areas within a room. A higher
capacity air conditioner may be required, depending on the size of the room
being heated up.
temperature. See "Operating mode description".
water, see "Draining the air conditioner". After draining, you can operate the unit.
too high. Lower set temperature. In heating mode: set temperature is too low.
Higher set temperature.
cooling/heating capabilities of your local air conditioner. Local air conditioners are
designed as supplemental cooling/heating to local areas within a room.
showers, etc.) in the room. Use a fan to exhaust heat or moisture from the
room. Try not to use heat-producing appliances during the hottest part of the day.
In heating mode the temperature of the environment is too high. Do not use
your air conditioner when the temperature of the environment is too high.
louvers are free from curtains, blinds, furniture, etc.
conditioner in the cooling mode when the outside temperature is below 18°C.