Operation With Rated Power (Normal Operation) - Lenze E82MVxxx 2B Serie Montageanleitung

0.25 ... 0.37 kw
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation with rated power (normal operation)

The data applies to operation with rated mains voltage and a switching frequency of 8 kHz
(sine). For data and restrictions for other switching frequencies: See operating
instructions.
Type
Power
E82EV251
E82EV371
1)
Currents for periodic load change: 1 min overcurrent time with I
75 % I
r
EDK82MV371 DE/EN/FR 7.0
Operation with rated power (normal operation)
Rated mains voltage
[kW]
P
rated
0.25
1 N PE AC 230 / 240 V or
2 PE AC 230 / 240 V:
180 V −0 % ... 264 V +0 %
0.37
45 Hz −0 % ... 65 Hz +0 %
l
Technical data
Mains
Output current [A]
current [A]
I
rated
3.4
1.7
5.0
2.4
and 2 min base load time with
max
3
I
max
1)
(60 s)
2.5
3.6
87