Assembly
Inserting/Replacing the Batteries (see figure A)
Alkali-manganese batteries are recommended for the measuring tool.
To open the battery lid 10, press the latch 9 in the direction of the arrow
and remove the battery lid.
Place the battery-recovery ribbon under the first battery being inserted.
Insert the supplied batteries in the sequence shown in the figure, paying
attention to the correct polarity.
Always replace all batteries at the same time. Only use batteries from one
brand and with the identical capacity.
 Remove the batteries from the measuring tool when not using it
for extended periods. When storing for extended periods, the batter-
ies can corrode and self-discharge.
Operation

Initial Operation

 Protect the measuring tool against moisture and direct sun light.
 Do not subject the measuring tool to extreme temperatures or var-
iations in temperature. As an example, do not leave it in vehicles for
longer periods. In case of large variations in temperature, allow the
measuring tool to adjust to the ambient temperature before putting it
into operation.
 Avoid hard knocks to the measuring tool or dropping it. Damaging
the measuring tool can cause accuracy to be compromised. Following
a hard knock or fall, carry out a check by comparing the laser lines or
plumb beams with a known horizontal or vertical reference line or ver-
ified perpendicular points.
Switching On and Off
To switch on the measuring tool, push the On/Off switch 15. Immediately
after switching on, the measuring tool sends a laser beam out of the exit
opening 8.
 Do not point the laser beam at persons or animals and do not look
into the laser beam yourself, not even from a large distance.
To switch off the measuring tool, push the On/Off switch 15 again.