Technical Data
Integrated galvanic isolation module (optional)
Electrical characteristics
Supply voltage
Power consumption
Reverse polarity protection
Isolation test voltage
RCM 880
Approvals
EU RO Mutual Recognition Type Approval Certificate
(Includes: ABS, BV, CCS, CRS, DNV, IRS, KR, LR, ClassNK, PRS, RINA, RS)

9.3 Characteristics Multi Sensor E03

E03
Measuring range
- Air humidity
- Temperature
- Air pressure
Measuring medium
Sensor length
Sensor diameter
Nominal pressure
Media temperature
Ambient temperature
Storage temperature
Degree of protection EN 60529
Electrical characteristics
Measuring element
Measuring insert
Accuracy
- Air humidity
- Temperature
- Air pressure
Electrical connection
- 48 -
24 VDC (16...32 V)
Yes (supply voltage)
300...1200 mbar abs.
Ambient air (non-aggressive gases)
not specified (atmospheric air pressure)
1 x digital sensor element for air humidity and temperature
1 x digital sensor element for absolute pressure
Not replaceable / filter cap replaceable
±2.5 % RH @ 10...90 % RH, 20...60 °C (typ.)
±1.0 mbar @ 950...1050 mbar (typ.)
4-pin sensor plug M12 x 1
<100 mA
1000 VDC
0...100 % RH
-40...85 °C
75 mm
10 mm
-40...85 °C
-40...85 °C
-40...85 °C
IP40
±0.3 K