Check the air supply for correct size and type of hose connectors. To
avoid loss of power or erratic action, ensure that there is no additional
drain on the air line and no moisture or restriction in the air pipe.
Storage:
Apply an ample amount of lubrication before storing the tool.
Run the tool for approximately 30 seconds after lubricating, in order to
ensure that the lubrication is uniformly distributed throughout the tool.
Store the tool in a clean and dry environment.
The following chart lists common issues and solutions. Please read it
carefully and follow all instructions closely.
WARNING!
Potential hazard that will result in serious injury or loss of life.
If any of the following symptoms appear while the tool is in use, turn it
off and disconnect it from the air supply immediately. Failure to heed
this warning will result in serious personal injury.
Disconnect the tool from the air supply before making any
adjustments.
Repairs must be performed by a qualified service technician only
PROBLEMS
POSSIBLE CAUSES
Tool runs at
. Motor parts worn.
normal
. Cam clutch worn or
speed but
sticking due to lack of
loses under
lubricant.
load
TROUBLESHOOTING
REMEDIES
- Lubricating clutch housing.
- Check for excess clutch oil. Clutch cases
need only be half full. Overfilling can cause
drag on high speed clutch parts, ie. a typical
oiled/lubricated wrench requires 1/2 ounce of
oil.
GREASE LUBRICATED:NOTE: Heat usually
indicates insufficient grease in chamber.
Severe operating conditions may require more
frequent lubrication.