for the user and the qualified installer
3.
Fault elimination by the user
Fault
No hot water despite fully opened hot
water fitting.
Table 3
4.
Fault elimination by the qualified installer
Fault
Flow too weak
Heating fails to switch on / no hot
water.
Table 4
5.
Waranty, environment and recycling
Warranty
The warranty conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products, it is increasingly the
case that warranties can only be issued by those subsidiaries.
Such warranties are only granted if the subsidiary has issued
its own terms of warranty. No other warranty will be granted.
We shall not provide any warranty for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.
16
Cause
No electrical power.
The turn on flow rate needed to switch on the
heating power has not been reached. Soiling or
furring of the jet regulator.
Cause
Jet regulator furred or soiled.
Filter soiled.
No electrical power.
Heating system defective.
The pressure limiter has released
Remedy
Check the fuses in the house installation.
Clean or if necessary renew the jet regulator
(see „Special accessories").
Remedy
Clean or if necessary renew the fitting jet
regulator (see „Special accessories").
Clean the filter in the cold water inlet A (2)
after shutting off the water supply.
Check the fuse (house installation).
Measure heating system resistance, if necessary
exchange the unit.
Determine and eliminate the cause for the fault.
Disconnect from power and relieve the pressure.
Reactivate pressure limiter E (a).