15.2 Wiring diagram

3/PE ~ 400 V
Priority control with LR 1-A
2
1
1 Control cable to the contactor of the 2nd appliance
(e.g. electric storage heater).
2 Control contact opens when switching the instanta-
neous water heater on.

15.7 Details on energy consumption

The product data complies with EU regulations relating to
the Directive on the ecological design of energy related
products (ErP).
Manufacturer
Load profile
Energy efficiency class
Annual power consumption
Energy conversion efficiency
Default temperature setting
Sound power level
Special information on measuring efficiency

15.3 DHW output

Connected load in kW
Rated voltage
Connected load in kW
Rated voltage

15.4 Application areas / conversion table

Standard specifica-
tion at 15 °C
Re-
sist-
ance
ρ ≥

15.5 Pressure drop

Pressure drop at taps at flow rate of 10 l/min
Mono lever mixer tap, approx.
Thermostatic valve, approx.
Hand shower, approx.

15.6 Fault conditions

DDLT PinControl 13 DDLT PinControl 18 DDLT PinControl 21 DDLT PinControl 24
222384
AEG Haustechnik
XS
A
kWh
469
%
39
°C
-
dB(A)
15
None
The DHW output is subject to the mains voltage, the ap-
pliance's connected load and the cold water inlet temper-
ature. The rated voltage and rated output can be found on
the type plate (see chapter «Troubleshooting»).
38 °C DHW output in l/min.
Cold water inlet temperature
400 V
13.5
18.0
21.0
24.0
50 °C DHW output in l/min.
Cold water inlet temperature
400 V
13.5
18.0
21.0
24.0
Specific electrical resistance and specific electrical con-
ductivity (see chapter «Data table»).
20 °C
Conductivity
Re-
Conductivity
σ ≤
sist-
σ ≤
ance
ρ ≥
Ωcm mS/m μS/cm
Ωcm mS/m μS/cm
900
111
1111
800
Taps/valves
Sizing the pipework
When calculating the size of the pipework, a pressure
drop for the appliance of 0.1 MPa is recommended.
In the event of faults, loads up to a maximum of 95 °C
at a pressure of 1.2 MPa can temporarily occur in the
installation.
222385
AEG Haustechnik
AEG Haustechnik
S
A
483
38
-
15
None
Installation
5 °C
10 °C
15 °C
20 °C
5.8
6.9
8.4
7.8
9.2
11.2
9.1
10.7
13.0
10.4
12.2
14.9
5 °C
10 °C
15 °C
20 °C
4.3
4.8
5.5
5.7
6.4
7.3
6.7
7.5
8.6
7.6
8.6
9.8
25 °C
Re-
Conductivity
sist-
σ ≤
ance
ρ ≥
Ωcm mS/m μS/cm
125
1250
735
136
MPa
0.04 - 0.08
MPa
0.03 - 0.05
MPa
0.03 - 0.15
222386
222387
AEG Haustechnik
S
A
483
38
-
15
None
None
10.7
14.3
16.7
19.0
6.4
8.6
10.0
11.4
1361
S
A
483
38
-
15
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis