Herunterladen Inhalt Inhalt Diese Seite drucken

telekom behnke myintercom Plus Anleitung Seite 58

Ip-video türstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instructions myintercom Plus IP video door intercom
GB
Additional modules
The reset key
performs a reset on the door
intercom station, after the tamper contact
has been triggered. Please make sure that the
housing cover of the IP door intercom station is
correctly installed and press the button
the safety relay for at least 2 seconds.
The safety relay terminals marked "Door open"
may be used to connect the open door function
(12 V DC/AC max. 9 W). With an external power
supply, it is possible to connect this function
to relay 1. Please note that the tension for the
open door function and relay 1 will always be
triggered together.
58
It is also possible to use a second additional
relay with this module. This relay may be used
to control a gate opening device for your garage,
a bar or exterior lights.
on
www.behnke-online.com

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für telekom behnke myintercom Plus

Inhaltsverzeichnis