1. After making sure the Rotation Switch is in the "Forward" position,
Tension Knob has been retightened, and the Power Feed Lever is in the
down (forward) position, press the Foot Switch to start feeding the cable
further into the drain. Make sure you can operate the Foot Switch while
having at least one hand on the cable at all times. Also make sure the
Rotation Switch on top of the Drain Cleaner and Power Feed Lever are
within reach.
WARNING! Only one person should operate the cable feed and the Foot
Switch. Do not operate the Drain Cleaner with one person controlling the
cable and another person controlling the Foot Switch. This can cause the
cable to kink, twist, and break, which can also lead to serious personal
injury.
2. If the cable becomes lodged (for example: in a narrow part of the drain,
in a drain trap, etc.), put the Power Feed Lever in the"neutral"position
and allow the cable to try and work itself past the obstruction.
If cable still won't pass obstruction, release pressure from the Foot
Switch and use sharp downward thrusts to try and pass obstruction.
Once cable is past, put the Power Feed Lever in the down (forward)
position, press the Foot Switch, and continue feeding.