17. Move Feed Lever to exactly between F and R settings, otherwise cable
will start moving in or out during this test.
18. Press the Foot Switch and note the direction of rotation of the drum. If
the Foot Switch does not control the Drain Cleaner's operation, do not
use the machine until the Foot Switch has been repaired.
19. The drum should rotate clockwise when seen from the front of the
drum. It will match the drum direction shown on the warning label and the
arrow on the drum. If the rotation is not correct, do not use the machine
until it has been repaired.
20. After inspection, set the Rotation Switch to OFF, dry off your hands,
and unplug the Drain Cleaner.
21. Once you've verified that the Drain Cleaner is in good working order,
inspect the work area where you will be using the machine.
Work Area Set-Up
1. Verify that work area has adequate lighting for the job.
2. Make sure work area is free of flammable liquids, vapors or dust that
may ignite. Sparks can be generated during Drain Cleaner operation. Do
not work in area until these sources of ignition have been identified and
corrected.
3. Choose a firm, stable location for the machine and operator that will
remain relatively dry. Do not use the machine while standing in water. If
needed, remove the water from the work area.
4. Verify the electrical outlet is properly grounded. A three-prong or GFCI
outlet may not be properly grounded. If in doubt, have outlet inspected by
a licensed electrician.
5. Make sure there is a clear, unobstructed path from the Drain Cleaner to
the electrical outlet.
6. Inspect the drain to be cleaned. If possible, determine the best access
point (s) to the drain, the size(s) and length(s) of the drain, distance to
tanks or mainlines, the nature of the blockage, presence of drain cleaning
chemicals or other chemicals, etc.
7. If there are chemicals present in the drain, read and adhere to the
specific safety measures required to work around those chemicals.
Contact the chemical manufacturer for required