Spherical foot in bearing plates

depending on the erection surface, support may be necessary.
64
3.14

Inspection by an expert

The "Büffel" must be checked after each use, but at least once a year. See also DGUV Regulation 55
"Winches, hoisting and pulling equipment"
3.15

General safety instructions

CAUTION!
WARNING!
Danger of injury due to improper operation!
Improper operation can cause severe injury or property damage. Therefore, it is
absolutely necessary to:
For all work, observe the safety instructions and warnings given in Chapters 2 to
2.7.
Carry out all work steps according to the information in these operating instruc-
tions.
Before starting work, ensure that all covers and guards are installed and that
they work properly.
3.16

Malfunction / remedy

Malfunction
Possible cause
The piston moves jerkily.
Air in the system.
The lifting piston does not
Too little oil in the system.
extend or only partially
extends.
It is difficult to push the piston
back to its start position
It is difficult to push the piston
back to its start position
LIFTING KIT
Remedy
Move the "Büffel" to working position
"A". Open the drain valve by turning
the handwheel to the left and push the
piston back to its start position until the
air stops hissing.
"Oil check", top up oil if low.
Press the bleed knob several times in working
position „A" or working position „B".
Press the bleed knob several times in
working position "A" or working position
"B".