9. Troubleshooting/recommendations

Fault
No delivery capacity
Insufficient pump capacity Front cover is clogged

10. Guarantee

The present device was manufactured and inspected according to the latest
methods. The seller warrants for faultless material and workmanship in accordance
with the legal regulations of the country in which the device was purchased. The
warranty period begins with the day of the purchase and is subject to the provisions
below:
Within the period of warranty, all defects which are to be attributable to defective
materials or manufacturing will be eliminated free of charge. Any complaints are to
be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the
purchaser or by third parties. Damage resulting from improper handling or
operation, incorrect setting-up or storage, inappropriate connection or installation or
Acts of God or other external influences are excluded from warranty.
Parts being subject to wear and tear, such as the pump wheel (impeller) and
mechanical shaft seals are excluded from warranty.
All parts were manufactured using maximum care and high-quality materials and
are designed for a long lifecycle. It should be understood, however, that the wear
and tear depends on the kind of use, the intensity of use and the internals of
maintenance. Complying with the installation and maintenance information
16
Possible cause
Power supply interrupted
Cable is defective
Motor block is defective
Pump is calcified, rotor has seized
Rotor is blocked by sand
Pump is taking in air
Water feature nozzle dirty/calcified
Hose system dirty
Hose is too long
Insufficient hose diameter
Outflow is positioned too high
Pump is taking in air
Remedy
Plug in the power plug
Check fuse
Dispose of pump
Dispose of pump
Dismantle pump and descale
Dismantle and clean pump
Change the set up location as specified
in the usage instructions
Pump is too close to the water surface
and is taking in air find a deeper
location
Clean front cover
Clean or descale nozzle
Clean hose and/or outflow
Shorten the hose
Use a hose with a larger diameter
Reduce required delivery head
Pump is too close to the water surface
and is taking in some air  find a
deeper location
7