 Completely immerse the pump in your pond. Water will penetrate into the pump
body.
 A water level of at least 20 cm is required for operation, so that the pump does
not take in air.
 Only operate the pump at a maximum immersion depth (  ) of 2 m!
 The water temperature must not exceed 35°C.
 The pump must be protected from freezing.
 You can switch on the pump by plugging the mains plug into the socket or
switch it off by pulling the mains plug back out.
 In order to avoid unnecessary soiling, position the pump in your pond above
the sludge deposits, and attach solidly and levelly (stone slab)!
 You can install the supplied water feature accessories according to your needs;
you can use your respective choice from the three water feature attachments
(18,19,20), always in conjunction with the telescopic riser (17) and three-way
diverter (16). To do so, the respective water feature nozzle (18,19 or 20) is
fitted directly onto the thin end of the telescopic riser. The riser pipe is
telescopic and its length can therefore be varied by about 10 cm.
 Alternatively you can also screw the hose connection (14) which is also
supplied directly into the pump outlet, for instance to operate a filter or stream.
 In the case of the WPS 1000 and 2000, the 1/2" external thread to 3/4" internal
thread adapters also included in the delivery must first be installed directly on
the pump.
 The water feature set included in the delivery also has a ball head screw
connection (15) which should be installed directly between the pump and the
telescopic riser pipe or 3 way distributors. This screwed connection also
enables the riser pipe to be aligned vertically if the pump is positioned at a
slight angle. To do this, the locking nut must be unscrewed slightly before the
adjustment is made. After adjusting, re-tighten the locking nut well by hand.
 Always ensure that the seals we supply are properly in place and the relevant
parts are cleanly screwed together. Never use force or an unsuitable tool to try
to connect the parts.

7. Maintenance and care

To significantly extend the service life of your pump, and to ensure trouble-free
function, we recommend regular maintenance and cleaning. With a few hand
movements every user can easily execute all maintenance tasks. For this, the
pump must be dismounted, as described in chapter 8. All parts can be cleaned with
a non-metallic brush and a neutral cleaner. Ensure that the cleaning agent does not
get into the pond water. Carefully rinse off all cleaned parts with clean tap water,
before putting the pump back together and placing it in service. If the pump is
heavily calcified, you can place the run unit and the motor block in a descaling
solution for stainless steel parts. In this regard comply with the use instructions
provided with the descaling agent.