Installation
General requirements
14
During operation, the heat pump will produce condensation that drains from its base . Before
securing the heat pump in place, ensure the supplied condensate drainage kit is properly
connected and directed to a drain or soak-away .
Components are secured to the heat pump base with screws or bolts, and while every effort
is made to seal these fittings, small amounts of condensation may still leak through the base .
The heat pump should be mounted using the provided anti-vibration mounts or M10 bolts,
either on a level concrete base or securely fixed mounting brackets . Ensure that all fixings and
brackets are corrosion-resistant .
NOTICE
Improper heat pump location or installation can lead to reduced performance, resulting in
longer pool heating times, failure to reach the desired temperature, and higher energy costs .
WARNING
Risk of electric shock due to incorrect heat pump location .
To meet safety regulations for electrical installations in wet areas, the heat pump must be
positioned at least 3 .5 meters away from the edge of the pool or spa .
Distance >3.5m
The heat pump uses R32 refrigerant . For safe handling, storage, and installation, please refer
to the sections titled Transportation, Handling, and Storage as well as Refrigerant Type
and Installed Location on the following page .
Fit condensate adaptor into hole in
heat pump base and attach drainage hose
Heat pump
Swimming pool or spa
Accessories: General requirements