Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Of Motor Bearing - Sumitomo PARAMAX 9000 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für PARAMAX 9000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PA R A M A X 9 O p e r a t i n g M a n u a l

9.4 Maintenance of motor bearing

The following instructions apply when using SUMITOMO standard 3-phase motor .
Refer to the relevant instruction manual when using motors with brake, servomotors , DC
motors and motors made by other companies.
Bearing types and maintenance methods vary according to the frame sizes of the unit.
Choose the proper maintenance method by checking the nameplate and the bearing type in
Table 24.
Bearing Type
Sealed bearing
Open bearing
Maintenance of sealed bearing
Since sealed-type bearing is filled with high quality grease from the factory, it is not necessary
to replenish grease at the initial operation. Under normal operation, exchanging bearing once
every three-five years or every 20,000 hours at disassembly or maintenance is recommended
for reliable operation.
Use CM class bearings.
Use "MULTEMP SRL (Kyodo Yushi)" lubricants.
Under sever usage conditions, change bearing more frequently.
When using forced ventilating motor, replacement of cooling fan every 15,000 hours running is
recommended because the bearing life of fan motor is 15,000 to 20,000 hours.
Maintenance of open bearing
Grease replenishing time and quantity
Checking the bearing number in the nameplate, replenish grease in according to Table 25.
Table 25 Grease maintenance schedule
Bearing No.
6314
6315
6316
6317
6318
6319
6320
6321
6322
6324
6412
6413
6414
NU314
NU315
NU316
NU317
NU318
NU319
NU320
NU321
NU322
NU324
Initial quantity shows replenished quantity after disassembling and cleaning the bearings.
Supply about 1/3 of the quantity to inside of the bearing and the rest of it to inner space.
Replenishing quantity indicates grease amount poured into the bearing every interval.
Even though the bearing is run with intermittent operation, replenish grease at least every three
years.
Replenish grease right after starting operation after a long shut down.
PX9_DEU_ENG_11_2007_999345
Motor size
A-Side
225 or smaller
250 or smaller
Dimension
Initial quantity
Inner dia.
Outer dia.
Width
70
150
35
75
160
37
80
170
39
85
180
41
90
190
43
95
200
45
100
215
47
105
225
49
110
240
50
120
260
55
60
150
35
65
160
37
70
180
42
70
150
35
75
160
37
80
170
39
85
180
41
90
190
43
95
200
45
100
215
47
105
225
49
110
240
50
120
260
55
B-Side
250 or larger
Replenishing
Replenishing time (interval corresponding to rotation speed r/min)
quantity
(gram)
750r/min
(gram)
200
40
8500
230
45
8500
260
50
8000
300
55
7500
350
60
7000
400
65
7000
450
70
6500
500
75
6000
550
80
6000
700
100
5500
200
40
8500
230
45
8000
300
55
8000
120
40
4000
150
45
4000
200
50
4000
250
55
3500
300
60
3500
350
65
3500
400
70
3000
450
75
3000
500
80
3000
650
100
2500
Remarks
No construction for supplying or
draining grease
With grease nipple and drain
plug
900r/min
1000r/min
1200r/min
1500r/min
7000
6000
5000
3500
6500
6000
4500
3500
6500
5500
4500
3000
6000
5000
4000
3000
5500
5000
4000
2500
5500
4500
3500
2500
5000
4500
3500
2000
5000
4000
3000
2000
4500
4000
3000
2000
4000
3500
2500
1500
7000
6000
5000
3500
6500
6000
4500
3500
6500
5500
4500
3000
3500
3000
2500
1500
3000
3000
2000
1500
3000
2500
2000
1500
3000
2500
2000
1500
2500
2500
2000
1000
2500
2000
1500
1000
2500
2000
1500
1000
2500
2000
1500
1000
2000
2000
1500
1000
2000
1500
1000
Page 27
1800r/min
2500
2500
2500
2000
2000
1500
1500
1500
1000
1000
3000
2500
2500
1000
1000
1000
1000
1000

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis