Oil supply
Supply oil through the filling port on top of the main unit. Check the oil level with a dipstick or
visible oil gauge (Fig.27).
Screw the dipstick to its deepest position to check the oil level; otherwise, the measured oil
level will be incorrect (Fig.28).
Dipstick
Fig. 27
Care should be maintained during the oil-filling process to ensure that loose nuts, bolts, wash-
ers, dust, water and other such foreign material do not enter the unit.
Please remove drain plug located under the unit for oil draining when lubricating oil is still warm.
Removing the air breather makes draining and supplying oil easier.
Supplying and draining grease
1. Remove drain plug for grease in the hosing of gear part.
2. Remove the grease drain port plug, drain used grease and supply new grease by grease gun
from grease nipple.
Fill new grease up to draining it from grease drain port.
3. Put the drain plug back.
PX9_DEU_ENG_11_2007_999345
The oil level should be
within this range
Sight gauge (window type)
Sight gauge (pipe type)
Fig. 28