8. Operation
Do not touch rotating parts (output shaft, etc.) during operation; loose clothing may become
caught in these rotating parts and cause serious injury or death. ·
When the power supply is interrupted, be sure to turn off the power switch. Unexpected resump-
tion of power may cause electric shock, personal injury or damage to the equipment. ·
Do not operate the unit with the terminal box cover removed. Install the terminal box cover after
maintenance, in order to prevent electric shock. ·
Do not open the terminal box cover when power is supplied to an explosion-proof type motor;
otherwise explosion, ignition, electric shock, personal injury, fire or damage to the equipment
may result.
Do not put fingers or foreign objects into the opening f the gearmotor or reducer; possible elec-
tric shock, personal injury, fire or damage to the equipment may result. ·
The gearmotor or reducer is very hot during operation. Touching the unit may result in burns. ·
Do not loosen the oil filler plug during operation; otherwise, hot, splashing lubricant may cause
burns. · If a problem occurs during operation, stop operation immediately; otherwise, electric
shock, personal injury or fire may result. ·
Do not operate the unit in excess of the name plate rating; possibly, personal injury or damage
to the equipment may result.
Paramax drives are shipped without oil. Units must be filled with the proper amount of recom-
mended oil prior to start-up.
After the unit is installed, filled with oil and properly wired, check the following before operat-
ing:
- Is the wiring correct?
- Is the unit properly coupled with the driven machine?
- Are foundation bolts tightened to the proper torque value?
- Is the direction of rotation as required?
When all of the above questions are positive, conduct a trial run with light load. Move on to
actual operation after confirming that are no abnormal sound, vibration, and temperature rise.
Check the items shown in Table 15.
Do you hear or feel
abnormal sound
or vibration ?
Is the surface tempera-
ture of the PARAMAX
DRIVE or reducer
abnormally high?
In case of any problems switch off the equipment and contact next service point.
Page 20
1. Is the housing deformed because the installation surface is not
flat?
2. Is insufficient rigidity of the installation base generating exces-
sive noise?
3. Is the shaft center aligned with the driven machine?
4. Is the vibration of the driven machine transmitted to the gearmo-
tor or reducer?
1. Is the voltage rise or drop substantial?
2. Is the ambient temperature too high?
3. Does the current flowing to the motor exceed the rated current
shown on the rating plate?
4. Is the oil level specified level?