5.Drive mode setting
05P is the drive mode setting. The available drive modes
are: 00-Pedal assist only, 01-Electric only, 02- Both
Pedal assist and electric.
Press [ ] to enter the parameter changing state.
Press the [ ] / [ ]to select the parameter and press
[ ] to save the parameter setting and return to the
personalized parameter setting interface.
6.Start-up setting
06P is the Pedal assist strength setting, The Pedal assist
strength is the relative strength of the PWM signal from
the controller when stat to activate pedal assist. The
adjustable range is 0 ~ 5. 0 is the weakest strength and
5 is the strongest.
Press [ ] to enter the parameter changing state.
Press the [ ] / [ ]to select the parameter and press
[ ] to save the parameter setting and return to the
personalized parameter setting interface.
7.Controller Current Limit Setting
07P is the controller current limit setting. The adjustable
range is: 1~50A.
Press [ ] to enter the parameter changing state.
Press the [ ] / [ ]to select the parameter and press
[ ] to save the parameter setting and return to the
personalized parameter setting interface.
13
Figure 5-Drive
mode setting
interface
Figure 6-Pedal assist
Figure 7-Controller
Start-up intensity
current limit setting
setting interface
interface