3.Use a wrench to remove the Nozzle Tip Guard(Q) and Nozzle Spray Tip (P) from
the gun and place it into the cleaning fluid.
4.Use a pair of wrench and remove the Inlet port (V) from the gun.
5.Move the handle guard out of the way and use a wrench to remove the Handle
(T) from the upper body of the spray gun.
6.Remove the mesh filter from within the Handle (T} and place it into the cleaning
fluid.
7.Use a soft brush to clean all components in the cleaning fluid.
8.Once cleaning is completed, reassemble the spray gun.
STORING THE SPRAYER
It is very important that the Sprayer is NOT stored with water or water-based
materials inside the pump, hose, tubes, or spray gun. Water remaining within
these items will cause corrosion and damage them. Follow these procedures to
store the sprayer.