TESTING
1. Turn on the power.
2. Remove the motor/tank cover assembly and hold level.
3. Test the motor switch by raising the motor switch float with a finger
(Figure 6). The motor should turn on just before the float contacts cover.
4. Test the safety switch by raising the safety switch float with a finger. The
safety switch should activate before the float contacts cover.
5. Replace the motor/tank cover assembly on the tank.
This pump is suitable for gas furnace condensate applications. Caution
must be taken to ensure the acidity of condensate does not increase below
the average pH of 3.4 (to prevent localized pocket of acid that acts like a
battery causing pitting) by routinely cleaning or flushing the tank with fresh
water.