INSTALLATION
1.Before installing the pump, allow the air conditioner to cycle several
times, collecting condensate in a separate container to help flush any
residual oils that may remain in the system.
2.Carefully unpack the pump. Remove the cardboard packing from the
motor cover air slots. Carefully slide the packing away from the pump. This
packing is used to prevent switch movement during shipment (Figure 1).
3.Mounting the pump: the tank has two slots provided to mount the unit.
The slots are located on the ends of the tank (Figure 5). The unit should be
mounted either on the side of the air conditioner unit or a nearby wall. The
pump must be level, and the inlet must be below the coil drain. Conduit
fittings are not compatible with the plastic pump housing.
4.The pump should not be installed in a manner that will subject it
tosplashing or spraying.
5. This pump is not intended for use inside air plenums.

ELECTRICAL CONNECTIONS

WARNING
1.Shut off the electrical power at fuse box before making any connections.
All wiring must comply with local codes.
2.Line voltage: Connect the power cord to the line voltage specified on the
motor and nameplate. The power cord must be connected to a constant
source of power (not a fan or other device that runs intermittently). If the
power cord does not have a plug, wiring is as follows: green (or
green/yellow)-ground. Black (or brown)-line. White (or blue)-neutral.
3.Safety switch: The safety overflow switch should be connected to a class