Product specification
Item number
Rated voltage
Charger type
Connection to vehicle
RDC-DD
Grid type
Overheat protection
Operating temperature
Storage temperature
Dimensions (D x W x H)
Enclosure material
Impact resistance
Ingress protection
Weight
Certifications
Rated impulse withstand voltage Uimp
Rated short-time withstand current Icw
Rated conditional short-circuit current Icc
Rated current of a circuit Inc
Rated peak withstand current Ipk
ACSEV
Overvoltage category
Pollution degree
EMC environment
Recycling
Integrated MID energy meter
Accuracy
Harmonized standard
Notified body
Referance voltage Un
Reference frequency fn
Rated current (Ist / Imin / Itr / In / Imax)
Meter constant
Repeatability test; minimum pulses
Environment
1
Charging unit can be used within temperature range -40°C to +50°C when MID metering is not required.
defa.com
715003
380-420 Vac (Three phase, 50-60 Hz)
220-240 Vac (Single phase, 50-60 Hz)
Mode 3
Type 2
6mA DC in accordance with IEC 62955
TN/IT/TT
Internal sensors
-30°C to +40°C
1
-50°C to +85°C
128 x 167 x 350 mm
Polycarbonate
IK10
IP55 (Wall bracket IP44)
8.5 kg
CE, IEC61851, IEC62955, IEC61439-7 ACSEV, MessEG, MessEV
4 kV
1520 A @ 1.2 ms
10 kA
32 A
2280 A (IEC 61439-1 Table 7 nxIcw, n = 1.5)
ACSEV
III
III
Class A and B
E-waste
Class B (±1 %)
EN 50470-1:2006, EN 50470-3:2006
VDE Prüf- und Zertifizierungsinstitut GmbH
3x 230 V / 400 V
50 Hz
0.02 / 0.25 / 0.5 / 5 / 32 A
1000 pulses/kWh
1000 (1/10th of permissible error)
M1 and E2
39