5.10

Service diagnostic parameters (read only)

Service diagnostic parameters (read only)
P60
Number of operating hours since issuing [h]
P61
The number of operating hours since the last power-on [h]
P62
The number of operating hours of the relay (closed time of contact C2) [h]
P63
The number of switching cycles of the relay
P64
The current temperature of the device's electronics [°C / °F]
P65
The highest temperature of the device ever measured [°C / °F]
P66
The lowest temperature of the device ever measured [°C / °F]
P70
Number of detected peaks (current)
P71
Magnitude of selected echo (raw value)
P72
The amplitude of the selected echo [dB]
P73
The distance of the selected echo [m]
P74
Echo lost/shot ratio
5.11

Flow measurement control parameters (read only)

Service diagnostic parameters (read only)
P76*
Measuring height of the flow measurement ('h' value)
P77
TOT1 totalizer (can be cleared)
P78
TOT2 totalizer
5.12

Output control parameters (read only)

Service diagnostic parameters (read only)
P79
Current generator re-measured output current [μA]
P80
Current generator calculated output current [mA]
P81
Relay output status
5.13

Hardware / Software versions (read only)

Service diagnostic parameters (read only)
P94/P95
Software code 2 / 3 (SLAVE MCUs)
P96
Software code 3 (MAIN MCU)
P97/P98
Hardware identification code
Type 2298 80 GHz Radar Level Sensor
* Measuring height required for flow
measurement. This value is the "h"
value in the flow calculation formula.