Herunterladen Inhalt Inhalt Diese Seite drucken

Storage Conditions - +Gf+ 2298 Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Instruction manual
3.3.3
Function
3.3.4
Conditions for safe operation
Compliance with technological process conditions
► If the device is installed in a place subject to overvoltage, the device must be protected with at least class II surge protection!
► The device must be connected to the earth of the EP network via its earth screw.
The cable outside of the device must be secured and unencumbered!
The device operated from a power supply complying with Class 2 surge protection (SELV/PELV).
Compliance with local rules and regulations
The Type 2298 is a Local Positioning Radar (LPR) and must be mounted in a fixed, antenna-down position. In addition, the following
two restrictions on antenna placement and height from the ground must be observed:
► a separation distance of 4 km (2.48 miles) from radio astronomy sites operating in the frequency band 75...85 GHz, unless spe-
cifically authorized by the ruling national regulatory authority.
► At a distance of between 4 and 40 km (2.48 and 24.8 miles) from any radio astronomy site, the height of the radar above ground
level must not exceed 15 m (49.2 ft).
3.3.5

Storage conditions

When not in use, the device must be stored within the ambient temperature specified in the technical data and at a maximum humid-
ity of 98%.
Type 2298 80 GHz Radar Level Sensor