Type 2298 80 GHz Radar Level Sensor
5.6.2
P22 User slope correction factor (actual/measured)
FACTORY DEFAULT: 1.0
The parameter P22 corrects the transmitted quantity according to the distance. If the value measured by the device differs from the
value under real conditions, this multiplier can be used to refine the result. The output value is multiplied by the number set here. By
default, the multiplier (1) does not modify the output.
Value range: 0.7...10
P22
Measurement optimalization ➙ Velocity user
EView2
correction factor
5.6.3
P25 Echo selection
FACTORY DEFAULT: 00
The parameter P25a sets the echo selection strategy. Automatic operating mode is suitable for most applications. For special appli-
cation requirements, a specific echo selection can be set as required.
P25
a
Measurement optimalization ➙ Echo selection ➙ Selection of
EView2
Echo...
a
Echo selection within measuring window
0
Automatic
1
First
2
Second
3
Largest
4
Last