• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
• At low temperatures below +5°C, sluggishness may
make starting difficult or impossible.
8.4 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (11) upwards to switch on the
compressor. To switch off the compressor, press the
ON/OFF switch (11) down.
8.5 Setting the pressure: (Fig. 4)
Use the pressure regulator (3) to set the pressure on
the pressure gauge (5).
The set pressure can be drawn from the quicklock
coupling (Fig. 1/Pos. 4).
8.6 Setting the pressure switch
• The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar.
9. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cable used must also comply with these
regulations.
When working with spray attachments and during
temporary use outdoors, the device must be connect-
ed to a residual current circuit breaker with a trigger
current of 30 mA or less.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the wall
outlet. Cracks due to the insulation ageing. Such
damaged electrical connection cables must not be
used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F". The
printing of the type designation on the connection ca-
ble is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
10. Cleaning, maintenance and storage
n Important!
Pull out the power plug before doing any cleaning and
maintenance work on the equipment. Risk of injury
from electric shock!
n Important!
Wait until the equipment has cooled down complete-
ly! Risk of burns!
n Important!
Always depressurize the equipment before carrying
out any cleaning and maintenance work! Risk of in-
jury!
10.1 Cleaning
Keep the equipment free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or
blow it down with compressed air at low pressure.
We recommend that you clean the equipment imme-
diately after you use it. Clean the equipment regularly
with a damp cloth and some soft soap.
Do not use cleaningagents or solvents; these may
be aggressive to the plastic parts in the equipment.
Ensure that no water can get into the interior of the
equipment. You must disconnect the hose and any
spraying tools from the compressor before cleaning.
Do not clean the compressor with water, solvents or
the like.